1 AIT Asian Institute of Technology

The relationship between corrosion rate and half-cell potential

AuthorHsu Yee Win
Call NumberAIT Caps. Proj. no.CIE-17-21
Subject(s)Reinforced concrete--Corrosion
Electrochemistry

NoteA capstone project report submitted in partial fulllment of the requirements for the degree of Bachelor of Science in Engineering Civil and Infrastructure Engineering, School of Engineering and Technology
PublisherAsian Institute of Technology
Series StatementCaps. Proj. ; no. CIE-17-21
AbstractHalf-cell potential measurement is an electrochemical measurement make to know the severity of corrosion in reinforced concrete. It is very simple and inexpensive technique. This paper explains how much area of steel bar affected by corrosion with time by testing tensile test before and after corrosion of steel bar in order to make sure to calculate the reduced area of steel bar. After that, the concrete samples with various degree of corroded steels have been performed the half-cell potential to get the percentage of corrosion specifically by length of the bar.
Year2017
Corresponding Series Added EntryAsian Institute of Technology. Caps. Proj. ; no. CIE-17-21
TypeCapstone Project
SchoolSchool of Engineering and Technology (SET)
DepartmentDepartment of Civil and Infrastucture Engineering (DCIE)
Academic Program/FoSCivil and Infrastructure Engineering (CIE)
Chairperson(s)Tian Ho Seah;
Examination Committee(s)Chao, Kuo Chieh ;Thanakorn Pheeraphan;
DegreeCapstone Project (B.Sc.)-Asian Institute of Technology, 2017


Usage Metrics
View Detail0
Read PDF0
Download PDF0